We are an Authorized distributor for Copeland Climate Technologies Flow Controls. Formerly Alco Controls and Emerson Climate Technologies.
Friday, January 18, 2008
Electrical Control Valves
Improved energy efficiency, tighter temperature controls, wider range of operating conditions, remote monitoring and diagnostics functions.
Check with your local wholesaler for details.
Friday, January 11, 2008
200 Series Solenoid Valve
R12 Liquid line application 8.7kW - 97.6kW
R134A Liquid line application 10.4kW - 117.5kW
R22 Liquid line application 11.0kW - 124.0 kW
R407C Liquid line application 10.3kW - 128.0kW
R404A/507 Liquid line application 7.4kW - 81.4 kW
R502 Liquid line application 7.1kW - 80.4kW
For other applications, capacities and performance information, please seek advice from your local wholesaler.
240 Series Solenoid Valve
R134A Liquid line application 52.5kW - 307.4kW
R22 Liquid line application 55.2kW - 338.0 kW
R407C Liquid line application 52.4kW - 321.0kW
R404A Liquid line application 36.5kW - 230.0 kW
For other applications, capacities and performance information, please seek advice from your local wholesaler.
Thursday, December 27, 2007
Featured Products- Solenoid Valves from Emerson Climate Technologies
With Emerson® flow control products, you not only get the industry’s leading technology and products, you also get the expertise and support of Emerson Climate Technologies standing behind you. Our solenoid valves, provide the lowest leak rates in the industry. The patented-design coil clip, along with a more versatile coil housing, makes assembly quick and easy. One coil fits all valves.
Literature
Cutaway
White Paper
Contractor Tip Cards
Flow Controls
Literature
Cutaway
White Paper
Contractor Tip Cards
Flow Controls
Indications Without Insight Aren’t Really Indications At All
Moisture indicators on HVACR systems have been billed as critical early-warning components in the fight to cut the long-term effects of water damage and reduce repair and maintenance costs. But do they truly live up to their billing? And even more important, are they the answer to the changing demands the coming HFC refrigerants will place on systems?
Traditionally, moisture indicators have been green/yellow wafers that said the system was either “dry” (green) or “wet” (yellow). But, this simply does not go far enough. Here’s why. [More]
Traditionally, moisture indicators have been green/yellow wafers that said the system was either “dry” (green) or “wet” (yellow). But, this simply does not go far enough. Here’s why. [More]
Thursday, December 20, 2007
Electrical control valve
- Fully hermetic design
- Stepper motor driven
- Short opening and closing time
- High resolution
- Excellent repeatability
- Positive shut-off function to eliminate use of additional solenoid valve
- Bi flow version for heat pumps
- High linear flow capacity
- Wide capacity range
- Continuous modulation of mass flow, no stress (liquid hammering) in the refrigeration circuit
- Direct coupling of motor and valve for high reliability
- Ceramic slide and port for high accurate flow and minimal wear
- Corrosion resistant stainless steel body
- Straight through
- Compatiable with all CFCs, HCFCs and HFCs
- Balanced force design
- Europe patent no. 0743476, USA patent no. 5735501, Japan patent no. 28225789
Subscribe to:
Posts (Atom)